Fiber optic Arc Fusion Splicer Machine
Description:
1 |
Applicable Fiber |
Single mode and multi mode silica basedoptical glass fiber·Cladding diameter :100 –150um·Coating diameter :0.1-1.0mm |
Cleave Length |
Standard spec :16mm | |
2 |
Mean Splice Loss (Note 1)
|
·Single mode fiber : Typ.0.02dB·Dispersion shifted fiber : Typ.0.04dB·Multi mode fiber : Typ.0.01 dB |
Mean Splice Time (Note 2) |
8 seconds | |
Fiber Protection Sleeve Shrinking Time (Note 3) |
40mm/60mm sleeve : Typ.40seconds | |
3 |
Dimensions |
142mm(W)/122mm(D)/138mm(H) |
Weight |
1.95 kg | |
4 |
AC Adapter |
·Input: 100~240V(50~60Hz)·Output: 12V 3A |
5 |
Proof Test Force |
·1.96N(200gf) |
6 |
Program test
|
![]() |
Wind Resistance |
Maximum permissible wind velocity: 15m/s | |
7 |
Type of Splice Mode | AUTO,MANUAL |
Program of Splice Mode |
SM、MM、DS、NZDS、ER | |
Fiber Protection Sleeve Shrinking |
60mm, 40mm,and other micro protection sleeve | |
Heating |
User program | |
Storage of Splice Results |
Maximum permissible wind velocity: 15m/s |
Note 1:Mean splice loss:Data based on splicing same-type fibers having an average quality according to the ITU-T standard.
Note 2:Mean splicing time:Length of time from the start of operation by pressing START till the end of loss estimation.
Note 3:fiber protection sleeve shrinking time
·Length of time from the start of heating by pressing <>till the end of cooling.
Components: