ODVA(MPO/MTP) Outdoor Cable Assemblies 12 Core/24 Core
Description:
ODVA(MPO/MTP) BBU RRU Patch Cable is for CPRI application,that widely used in 3G,4G ,5G and WIMAX base station, Long term Evolution(LTE),and Remote Radio Units to the FTTA connectivities.TTI’S ODVA(MPO/MTP) BBU/RRU cable assemblies have passed tests like salt mist, vibration and shock and meet protection class ip67.these patch cables are always sealed with rugged fiber terminal junction boxes that meet the requirements of more antennas on a wireless tower.
Features:
♦ Cost effective solution for in house termination. 2.Low insertion loss and added loss.
♦ Height of attenuation.
♦ IP67 water, dust proof and corrosion resistant
♦ The material in the jumpel cable are all-weather and UV-resistant. 6.Mechanical performance: IEC 61754-7 standard.
Application:
♦ Multi-purpose Outdoor.
♦ For connection between distribution box and RRH.
♦ Deployment in Remote Radio Head cell tower applications.
Type |
Reference |
Note |
|
MPO/MTP | IEC 61754-7 | Single mode | APC: Green connectors PC: Yellow connectors |
Multimode | PC: Aqua Connectors(om3) Aqua or Purplish Connectors(om4) |
||
LC/SC/ST/FC | IEC 61754 | Single mode | APC: Green connectors UPC: Blue connectors |
Multimode | PC: Gray or Aqua Connectors(om3) Aqua or Purplish Connectors(om4) |
Assembly Structure Schematic Diagram
1. DVA(MPO/MTP) Outdoor Cable Assemblies
2. DVA(MPO/MTP) Outdoor Cable Assemblies(Method A, Method B, Method C)
3. Patch cord versions
Jumper tolerance requirement |
|
Overall length (L) (M) |
length of tolerance(CM) |
0<L≤20 |
+10/-0 |
20<L≤40 |
+15/-0 |
L>40 |
+0.5%L/-0 |
Optical Characteristics
1. MPO&MTP Optical Characteristics
Item |
Parameter |
Reference |
|||
|
Single mode |
Multimode |
|
||
Insertion loss |
Max≤0.75dB
|
Max≤0.7dB
|
IEC 61300-3-34 |
||
Return loss |
≥ 45dB (PC) ≥ 60dB (APC)
|
≥25dB
|
IEC 61300-3-6 |
2. LC/SC/ST/FC Optical Characteristics
Item |
Parameter |
Reference | |
Single mode |
Multimode |
||
Insertion loss |
Maximum≤0.30 |
Maximum≤0.30 |
IEC 61300-3-34 |
Return loss |
≥ 60dB (APC); ≥ 50dB (UPC) |
≥30dB |
IEC 61300-3-6 |
Cable Structure
Item | Date | |
Fiber | OS2,OM1,OM2,OM3,OM4 | |
Tension member | Aramid Kevlar | |
Max. attenuation | SM:≤0.36dB/km at 1310nm,≤0.22dB/km at 1550nm | |
MM:≤1.0dB/km at 1300nm,≤0.30dB/km at 850nm | ||
Out sheath Diameter(mm) | 7.0 | |
Inner sheath Diameter(mm) | 3.0 | |
Cable Material | LSZH/PE | |
Weight(KG/km) | 35 | |
Cable Color | Black | |
Tensile resistance | long term | 250 N |
short term | 600 N | |
Crush resistance | long term | 300 N/100m |
short term | 800 N/100m | |
Bending Radius | Static | 20D |
Dynamic | 10D | |
Temperature | -20~70℃ |
Item | Date | |
Fiber | OS2,OM1,OM2,OM3,OM4 | |
Tension member | Aramid Kevlar and SUS Spiral armoured | |
Max. attenuation | SM:≤0.36dB/km at 1310nm,≤0.22dB/km at 1550nm | |
MM:≤1.0dB/km at 1300nm,≤0.30dB/km at 850nm | ||
Out sheath Diameter(mm) | 7.0 | |
Inner sheath Diameter(mm) | 3.0 | |
Cable Material | LSZH/PE | |
Weight(KG/km) | 45 | |
Cable Color | Black | |
Tensile resistance | long term | 600 N |
short term | 1000 N | |
Crush resistance | long term | 1000 N/100m |
short term | 3000 N/100m | |
Bending Radius | Static | 20D |
Dynamic | 10D | |
Temperature | -20~70℃ |